Shijiazhuang Mingshuo Electric Power Technology Co., Ltd.
Contact us
Service: 400-116-5838
WhatsApp:86-18532175010
Email:roger@msdlkj.com
No. 1 Ganjiang Road, Shijiazhuang Economic and Technological Development Zone, Shijiazhuang City, Hebei Province
ZBW-12 Smart Integrated Substation (American Style)
- Product Description
-
Product Overview
1. Fully insulated, fully sealed, maintenance-free, and reliably ensuring personal safety.
2. Compact in design, with a volume only 1/3 to 1/5 that of conventional transformers of the same capacity; its height is just 1.5 units, ensuring unobstructed visibility.
3. A compartmentalized structure is used to prevent oil contamination within the transformer tank.
4. The high-voltage side features dual-fuse full-range protection, significantly reducing costs.
5. It can be used with ring networks as well as in terminal applications, and the cable connectors can be urgently plugged and unplugged even under a 200A load current.
6. The enclosure features a honeycomb-style, double-layer composite panel that provides both excellent insulation and effective heat dissipation.
7. An undervoltage controller can be installed on the low-voltage side, enabling rapid disconnection of the low-voltage load when abnormal voltage conditions occur within the system.
8. High-voltage oil-immersed load switches or SF6 load switches can be automatically upgraded, laying the foundation for achieving distribution network automation.
Uses
Widely used in urban grid upgrades, residential communities, and various public spaces, as well as indoor and outdoor locations such as factories, mines, hotels, airports, railways, ports, and highways.
Normal operating conditions
1. Altitude not exceeding 2500m.
2. Ambient temperature: -35°C to +40°C.
3. Relative Humidity: The daily average should not exceed 95%, and the monthly average should not surpass 90%.
4. Installation location: A place free from fire hazards, explosion risks, chemically corrosive gases, and with good ventilation; the floor inclination should not exceed 3°.
Implementation Standards
This product complies with the following standards: GB/T 17467-1998 "High-Voltage/Low-Voltage Prefabricated Substations"; and DL/T 537-93 "Technical Specifications for Ordering 6-35kV Box-Type Substations."
Ordering Instructions (Please specify when placing your order)
1. Main circuit scheme number, purpose, single-line system diagram, arrangement drawing, and distribution room layout plan, etc.
2. Schematic diagram of the auxiliary circuit wiring and terminal arrangement diagram.
3. Model, specifications, and quantity of electrical components within the switchgear.
4. Requirements for control, measurement, and protection functions of switchgear equipment, as well as requirements for other interlocking and automatic devices
5. If bus bridges are required to connect switchgear units or incoming feeder cabinets, please provide specific data such as the rated current-carrying capacity of the bus bridge, its span length, and the height from the ground.
6. When attachments or spare parts are needed, please specify the type and quantity required.
7. If switchgear is to be used under special environmental conditions, detailed specifications should be provided at the time of order.

Substation Layout and Structural Diagram
Figure 2: Outline and Structural Diagram of the ZBW-1210.4 Substation

1. High-voltage insulating bushing; 2. Ring main unit load switch; 3. Tap changer; 4. Plug-in fuse; 5. Low-voltage terminal
Figure 3: Outline and Structural Diagram of ZBW27M-1210.4 Substation

1. High-voltage insulating bushing; 2. Ring main unit load switch; 3. Plug-in fuse
Technical specifications
Capacity A B C H Weight KG 200 kVA and below 1830 1420 820 1850 Less than 2800 250-400kVA 1830 1450 850 1980 3000–3300 500-630kVA 1830 1480 880 2070 3600–3950 800kVA 2200 1700 950 2170 4500 *Note: The above are standard sizes for reference.
Capacity A B C H Weight KG 315kVA 2560 1600 600 1000 3050 400kVA 2560 1600 600 1000 3270 500kVA 2560 1600 600 1000 3400 630kVA 2560 1600 600 1000 3900 800kVA 2760 1600 800 1000 4200 1000kVA 2760 1950 800 1000 4800 1250kVA 2910 1950 800 1000 5400 1600kVA *Note: The above are standard sizes for reference.